Chr17212R LabVIEW Wrapper Conversion Report

2019¦~7¤ë2¤é ¤U¤È 03:43:43

Source Driver Information
Driver Prefix: Chr17212R
Total number of functions: 79
Driver Class: IviGeneral

LabVIEW Wrapper Driver Information
Total number of VIs: 62

Conversion Information
Basic

For best results, it is important to ensure that the source driver is fully compliant with the IVI Foundation specifications and all problems relating to the driver and function panel are resolved before running this tool. To help verify IVI compliance and detect possible problems with the driver, use the IVI Specific Driver Test Suite which can be found under Tools menu in LabWindows/CVI.
The following errors/warnings occurred when generating the wrapper for this instrument driver. Address each of these issues to complete the instrument driver VIs. Note that some of these issues may be a result of issues in the LabWindows/CVI driver. To resolve these types of issues, fix the problem in the LabWindows/CVI driver and regenerate the LabVIEW interface. Contact instrument.drivers@ni.com for technical assistance.

Constant Array Size to Allocate Indicator
The following instrument driver VI(s) have string or array indicators. The utility uses a constant to allocate memory for the indicator. Review the block diagrams of the VI(s) to ensure that the appropriate size is allocated for the indicator. The block diagram constant used to allocate array size or string size should be adjusted so that it is large enough to accommodate all valid values for the indicator. If the DLL function in the generated VI(s) has a size parameter, delete the block diagram constant and wire the size control to the size input of the Initialize Array function.
    Chr17212R Read.vi -> Read Buffer
    Chr17212R Query Channel ID.vi -> Channel Identify
    Chr17212R Query Output State.vi -> Output State
    Chr17212R Query Source All.vi -> Type
    Chr17212R Query Source Mode.vi -> Mode
    Chr17212R Query Source DCIR.vi -> Type
    Chr17212R Measure All.vi -> Operation mode
    Chr17212R Measure DCIR.vi -> Operation Mode

Default Menu Palette Icon
Cannot match appropriate icons for the following menu (.mnu) palettes. Assign meaningful icons to the palette(s) by selecting Tools»Advanced»Edit Palette Views. Use the Icon Art Glossary for assistance with creating menu palette icons.
    dir - Application Functions
    dir - Obsolete
    dir - Application Functions - Channel
    dir - Application Functions - Specification
    dir - Application Functions - Source
    dir - Application Functions - Measure

Default VI Icon
Cannot match appropriate icons for the following VI(s). Assign meaningful icons to the VI(s) by right-clicking the icon in the upper-right corner of the VI(s) and selecting Edit Icon. Use the Icon Art Glossary for assistance with creating VI icons.
    Chr17212R Channel Source.vi
    Chr17212R Query Channel Source.vi
    Chr17212R Query Channel ID.vi
    Chr17212R Output State.vi
    Chr17212R Query Output State.vi
    Chr17212R Query Specification All.vi
    Chr17212R Query Spec Voltage High.vi
    Chr17212R Query Voltage Low.vi
    Chr17212R Query Spec Current.vi
    Chr17212R Query Spec Power.vi
    Chr17212R Query CR High.vi
    Chr17212R Query CR Low.vi
    Chr17212R Source All.vi
    Chr17212R Source Cutoff Time.vi
    Chr17212R Source Voltage.vi
    Chr17212R Source Current.vi
    Chr17212R Source Power.vi
    Chr17212R Source Cutoff Voltage.vi
    Chr17212R Source Cutoff Current.vi
    Chr17212R Source Mode.vi
    Chr17212R Source DCIR.vi
    Chr17212R Query Source All.vi
    Chr17212R Query Source Cutoff Time.vi
    Chr17212R Query Source Voltage.vi
    Chr17212R Query Source Current.vi
    Chr17212R Query Source Power.vi
    Chr17212R Query Source Cutoff Voltage.vi
    Chr17212R Query Source Cutoff Current.vi
    Chr17212R Query Source Mode.vi
    Chr17212R Query Source DCIR.vi
    Chr17212R Measure All.vi
    Chr17212R Measure Operation.vi
    Chr17212R Measure Time.vi
    Chr17212R Measure Protection.vi
    Chr17212R Measure State.vi
    Chr17212R Measure Voltage.vi
    Chr17212R Measure Current.vi
    Chr17212R Measure Power.vi
    Chr17212R Measure AH.vi
    Chr17212R Measure KWH.vi
    Chr17212R Measure DCIR.vi

Functions Unselected
The following functions are not selected. The LabVIEW Instrument Driver Import Wizard does not generate wrapper VIs for them.
    Chr17212R_GetError
    Chr17212R_ClearError
    Chr17212R_LockSession
    Chr17212R_UnlockSession
    Chr17212R_SetAttributeViInt32
    Chr17212R_SetAttributeViReal64
    Chr17212R_SetAttributeViString
    Chr17212R_SetAttributeViBoolean
    Chr17212R_SetAttributeViSession
    Chr17212R_GetAttributeViInt32
    Chr17212R_GetAttributeViReal64
    Chr17212R_GetAttributeViString
    Chr17212R_GetAttributeViBoolean
    Chr17212R_GetAttributeViSession
    Chr17212R_CheckAttributeViInt32
    Chr17212R_CheckAttributeViReal64
    Chr17212R_CheckAttributeViString
    Chr17212R_CheckAttributeViBoolean
    Chr17212R_CheckAttributeViSession