Regenerative Grid Simulator Model 61800HF Series

  • CE Mark
  • Rohs 2 Compliant
RegenerativeGridSimulator
RegenerativeGridSimulator
RegenerativeGridSimulator
RegenerativeGridSimulator
Caratteristiche principali
  • Rated power
    • 61830HF:30kVA
    • 61845HF:45kVA
    • 61860HF:60kVA
    • 61800-90HF:90kVA
    • 61800-120HF:120kVA
    • 61800-240HF:240kVA
    • 61800-360HF:360kVA
  • Voltage range: 0 to 460VLN
  • Frequency range: DC, 30 to 100Hz
  • High-power-density design: 5U/60kVA, 20U rack/120kVA, and 41U rack/360kVA
  • HV Mode supports output up to 920VLN* (61800-90HF, 61800-120HF, 61800-240HF, and 61800-360HF only)
  • Selectable single-phase and three-phase output modes
  • Split-phase output configurable through phase settings
  • Regenerates rated apparent power back to grid with 90% conversion efficiency
  • Adjustable voltage and frequency slew rate settings
  • Adjustable voltage and current output limits
  • Configurable voltage waveform turn-on/turn-off angle from 0 to 360°
  • Synchronous TTL transient signal for output voltage transitions
  • Advanced LIST, STEP, and PULSE modes for power line disturbance (PLD) simulation
  • Harmonic and interharmonic distorted waveform synthesis
  • Measurement functions including individual current harmonic components
  • Response Speed setting for output performance adjustment
  • Automatic fan-speed control algorithm minimizes fan noise
  • Standard USB and LAN interfaces
  • Optional GPIB and CAN interfaces
  • Higher output power through parallel configuration in single-phase and three-phase modes
  • Suitable for EV, PV inverter, and Smart Grid testing applications
  • Suitable for AI server power applications such as Power Shelf, Power Rack and SST systems
  • Meets OCP ORv3, M-CRPS, and (pre-compliance) ITIC requirements for AI server applications

*Call for availability.


Chroma 61800HF Series

The 61800HF Series spans three hardware architectures, from compact 5U benchtop models rated up to 60kVA to floor-standing rack models delivering up to 120kVA in 20U and 360kVA in 41U.

The Chroma 61830HF, 61845HF, and 61860HF are 30kVA, 45kVA, and 60kVA models in the 61800HF Regenerative Grid Simulator Series. Delivering up to 60kVA in a compact 5U chassis, these models set a new benchmark for power density. They support both single-phase and three-phase output with a maximum phase voltage of 460V and line voltage of 797V; through a single-phase three-wire configuration, the equivalent output voltage can reach up to 920V. For higher power requirements, units of the same power rating can be connected in parallel through master/slave control.

The Chroma 61800-90HF, 61800-120HF, 61800-240HF, and 61800-360HF scale the series into higher power classes of 90kVA, 120kVA, 240kVA, and 360kVA. An advanced series-parallel powerstage architecture combines multiple power modules to deliver up to 360kVA in a single rack. The same architecture allows the internal modules to be configured in series and parallel to support three-phase output with phase voltage up to 920V. Multiple racks can be paralleled to create an MVA-class test solution, meeting the high-power requirements of AI server applications such as Power Rack and solid-state transformer (SST) testing.

With energy recovery built in, the 61800HF Series supports testing across a broad range of cleanenergy applications, including solar PV inverters, energy storage systems (ESS), power conversion systems (PCS), microgrids, power hardware-inthe-loop (PHIL), electric vehicle supply equipment (EVSE), bidirectional on-board chargers (BOBC), and MVA-class bidirectional SSTs.

For power-related regulatory testing, the 61800HF Series supports vehicle-to-grid (V2G) and energy storage system (ESS) testing, IEC 61000-3-2/-3-3/-3-11/-3-12 AC power requirements, IEEE 1547 and IEC 62116 renewable-energy standards, SEMI F47 for semiconductor test equipment, and key AI server power specifications including OCP ORv3, M-CRPS, and ITIC.

The 61800HF Series employs all-digital control technology to deliver maximum power across an output range of up to 460V phase voltage and 30Hz to 100Hz frequency. All models provide high-purity sine waves with total harmonic distortion below 0.5% at full load at 50Hz/60Hz. DC and AC+DC output modes further extend coverage to DC-only testing and AC testing with DC bias.

The 61800HF Series also provides precise measurement capabilities, including RMS voltage, RMS current, real power, power factor, and current crest factor. Advanced DSP technology enables THD measurement and current harmonic analysis up to the 50th order. LIST, PULSE, and STEP programming functions support AC/ DC power line disturbance (PLD) simulation, while SYNTHESIS allows users to combine harmonic components into customized distorted waveforms.

The front panel combines a 5-inch LCD touchscreen with an intuitive UI and tactile physical keys for natural, efficient operation. Standard remote interfaces include USB and LAN, with optional GPIB or CAN, while Chroma SoftPanel enables PC-based remote digital control. Instrument drivers are also available for integration with LabVIEW-based control systems.

High Power Density Design, Outstanding Performance

Chroma 61830HF / 61845HF / 61860HF

Combining advanced digital control with next-generation thermal management, the Chroma 61830HF/61845HF/61860HF range delivers up to 60kVA in a compact 5U chassis. Compared with conventional solutions in the same power class, the benchtop form factor increases power density by 14.7 times while reducing space and weight requirements by more than 85%. The compact design also leaves more room for integration with other test equipment in a system rack, enabling more flexible power test configurations.

The benchtop models support wide-range phase-voltage output up to 460V, selectable single-phase and three-phase output, 100% power output in DC mode, and four-quadrant energy recovery. A high-bandwidth design delivers excellent transient performance and stability, with substantially faster output-voltage rise and fall response than previous 61800 Series products. Stable output characteristics and comprehensive protection features position these models for demanding power test applications.

Chroma 61830HF / 61845HF / 61860HF

Chroma 61800-90HF / 61800-120HF / 61800-240HF / 61800-360HF

An advanced modular power-stage architecture combines series-parallel design with precise synchronization to scale the series into 90kVA, 120kVA, 240kVA, and 360kVA rack models. The 61800-360HF delivers up to 360kVA in a single 41U rack. Compared with conventional 300kVA solutions that require three floor-standing cabinets installed side by side, the 61800-360HF provides 3.8 times the power density per unit footprint while reducing total system weight by more than 75%. These substantial improvements in space and weight establish the platform as a next-generation high-power AC source solution.

The rack models support phase-voltage output up to 460V and can automatically switch to HV Mode through internal relays for an expanded range up to 920V. They also provide three-phase output, 100% power output in DC mode, and four-quadrant energy recovery. Their unique series-connected module architecture, together with high-bandwidth and fast-transient performance, supports specialized high-voltage applications such as ITIC testing of server power systems and AC high-voltage testing of SST modules.

Chroma 61800-90HF / 61800-120HF / 61800-240HF / 61800-360HF

Voltage and Frequency Slew-Rate Settings

The Chroma 61800HF series allow users to define the slew rate of voltage or frequency output. When the output voltage or frequency changes, it transitions gradually to the final value according to the selected rate. This is especially useful for verifying the operating range of power products. For example, frequency can be ramped gradually from 47Hz to 63Hz, or voltage from 90V to 264V, instead of testing only fixed input points such as 90V, 115V, 230V, and 264V. During DUT power-up, voltage can also be ramped from 0V to reduce input inrush current, suitable for motor start-up or simultaneous power-on testing of multiple products.

Output voltage waveform change via voltage slew rate setting
Chroma 61860HF Regenerative Grid Simulator
Output voltage waveform change via frequency slew rate setting
Chroma 61860HF Regenerative Grid Simulator

The Chroma 6100HF series support both single-phase and three-phase output. Through the internal output relay architecture, users can switch automatically between these modes either from the touchscreen GUI or through interfaces such as LAN, GPIB, USB, and CAN. Even in single-phase mode, the system maintains 100% of rated full-power output, providing a highly versatile power testing solution.

Single-Phase
Chroma 61860HF Regenerative Grid Simulator
Three-Phase
Chroma 61860HF Regenerative Grid Simulator

*Benchtop models, including the 61830HF, 61845HF, and 61860HF, support both single-phase and three-phase modes, while all other floor-standing rack models support three-phase mode only.

Response Speed for Output Performance Adjustment

Different AC test applications demand different source characteristics, and DUT requirements generally fall along a transient-performance versus steady-state-stability spectrum. To address this, the Chroma 61800HF series introduce a new Response Speed adjustment function. Using precise digital control algorithms to modify response bandwidth, users can select Fast for higher transient performance, Medium for balanced behavior, or Slow for greater stability. With one-touch switching between modes, the AC source can be matched closely to the DUT and the desired test conditions.

Chroma 61860HF Regenerative Grid Simulator

Four-Quadrant Regenerative Grid Simulation

The Chroma 61800HF series are constant-voltage AC sources intended for general power testing of products such as home appliances, industrial power supplies, and switching power supplies. They support applications including simulation of utility abnormalities, harmonic voltage input, and user-defined waveform testing. With precise built-in protection settings, the platform can accommodate DUT loading conditions for test items such as inrush current and over-current/over-power behavior.

When testing products that return energy to the grid, such as solar PV inverters or bidirectional on-board chargers, the Chroma 61800HF series can detect reverse power flow from the DUT while outputting voltage and activate energy recovery. Reverse current and returned power are fed back to the AC grid at over 90% conversion efficiency rather than being dissipated as heat, delivering excellent energy-saving performance. This makes the platform a true four-quadrant AC source, capable of providing positive and negative voltage while supporting bidirectional current flow for comprehensive grid-simulation applications.

Positive Power
Chroma 61860HF Regenerative Grid Simulator
Negative Power
Chroma 61860HF Regenerative Grid Simulator

Grid-Connected Test Applications and Protection

Grid-connected Distributed Generation Compliance Testing

The Chroma 61800HF series support compliance-related testing for grid-tied distributed generation equipment, including UL 1741 SA, IEEE 1547, and IEC 62116. Major test items include:

  • Grid Voltage Abnormality Test
  • Grid Frequency Abnormality Test
  • Anti-islanding Test
  • Low Voltage Ride Through (LVRT) Test
  • Immunity Test: voltage variation immunity testing under IEC 61000-4-11 / -4-34
  • Limit Test: current harmonics and flicker limit testing under IEC 61000-3-2 / -3-3

Microgrid Testing

The Chroma 61800HF series can generate the distorted voltage and frequency conditions required for microgrid testing. Through energy recovery, power generated by the DUT can be returned to the AC grid at up to 90% efficiency, meeting microgrid test requirements. This product's AC input side already includes an isolation design, so no additional isolation device is required on the DUT side.

Chroma 61860HF Regenerative Grid Simulator

Grid-connection Safety Mechanism

The Chroma 61800HF series support both grid connection and energy recovery, and include a complete protection design for regenerative operation on the grid side. If the system detects abnormal AC conditions at the grid connection, such as overvoltage, undervoltage, abnormal frequency, three-phase imbalance, or overcurrent, it immediately issues an alarm and stops loading. At the same time, the grid-side power module enters a lockout state to protect user safety. Once normal grid conditions are confirmed, the system can be restarted and reconnected, providing a comprehensive grid-protection mechanism.

Advanced PLD Programming

The Chroma 61800HF series provide advanced PLD (Power Line Disturbance) programming functions for simulating a wide range of grid abnormalities and disturbance conditions. These include STEP, PULSE, and LIST modes, as well as harmonic- and interharmonic-related functions such as Synthesis, Inter-Harmonic, and Harmonic Measurement. STEP and PULSE modes support single-step or continuous voltage changes for simulating disturbances such as periodic voltage dips, transient overvoltage, and gradual voltage decline. LIST mode supports more complex waveform editing, with up to 100 programmable sequences and definable start and end states. Because waveform components can include both AC and DC, users can create nearly any required signal waveform. Together, these modes make it possible to simulate a wide range of voltage dips, interruptions, and waveform variations, and support IEC 61000-4-11 pre-compliance immunity testing as well as IEC 61000-4-13 / -4-14 / -4-28.

STEP Mode
Chroma 61860HF Regenerative Grid Simulator
PULSE Mode
Chroma 61860HF Regenerative Grid Simulator
LIST Mode
Chroma 61860HF Regenerative Grid Simulator

 

The new touchscreen interface further improves the usability of STEP, PULSE, and LIST functions. In LIST mode, for example, users can view settings for all sequences directly from the edit page and use search to locate the sequence they want to modify. Touch interactions such as tapping and swiping, together with quick editing tools such as copy and paste, make sequence programming more intuitive and efficient.

LIST Mode Main Page
Chroma 61860HF Regenerative Grid Simulator
LIST Mode Edit Page
Chroma 61860HF Regenerative Grid Simulator

 

The Synthesis function allows harmonic components up to the 50th order to be defined on a 50Hz or 60Hz fundamental, forming periodic distorted waveforms. Inter-Harmonic adds a non-harmonic variable-frequency component on top of the fundamental, with a sweep range from 0.01Hz to 3000Hz, helping users identify DUT input resonance points or immunity weak spots. Harmonic Measurement measures voltage or current harmonics up to the 50th order and displays values such as fundamental voltage, DC component, and total harmonic distortion.

Synthesis Function
Chroma 61860HF Regenerative Grid Simulator
Synthesis Preview Screen
Chroma 61860HF Regenerative Grid Simulator

 

Inter-Harmonic Function
Chroma 61860HF Regenerative Grid Simulator
Harmonic Measurement Function
Chroma 61860HF Regenerative Grid Simulator

Low-Voltage Ride-Through (LVRT) Test

When an abnormal grid-voltage event occurs (e.g., a voltage sag) a grid-connected PV inverter must maintain normal output for a specified period of time. The duration depends on the depth of the sag. For example, under the German BDEW standard, when voltage drops to 15% of nominal, the inverter must maintain normal output for 150ms. In addition to meeting the required ride-through duration, an LVRT-capable PV inverter must also generate reactive power that correctly corresponds to the sag depth.

Using the advanced LIST Mode programming function, the Chroma 61800HF series can set output voltage and timing step by step according to the required test curve, allowing users to build LVRT test conditions with precision. The Synthesis function can also be used to simulate grid voltages with different harmonic components, making it possible to evaluate their impact on PV inverter output current THD. Together, these capabilities make for a precise and comprehensive LVRT test solution.

LVRT Stage Voltage / Time Settings

Test number U/UN LVRT duration (ms)
1 ≦0.05 ≧150
2 0.2 - 0.5 ≧550
3 0.45 - 0.55 ≧950
4 0.7 - 0.8 ≧1400
LVRT Test Curve
Chroma 61860HF Regenerative Grid Simulator

Power Hardware-In-The-Loop (PHIL) Applications

The Chroma 61800HF Series support external analog signal input, a key requirement for high-power power hardware-in-the-loop (PHIL) simulation. This allows analog signals generated by real-time digital simulators such as RTDS and OPAL-RT, or by arbitrary signal generators, to be amplified accurately. A major technical advantage is the system's extremely fast dynamic response: latency from external signal input to actual voltage output is under 100μs. This low-latency performance helps maintain simulation-loop stability and enables realistic reproduction of complex grid transients and dynamic behavior.

*All proprietary names mentioned belong to their respective owners.

Chroma 61860HF Regenerative Grid Simulator

Master/Slave Parallel Output Mode

Chroma 61830HF / 61845HF / 61860HF

Through a master/slave architecture that links one master unit with additional slave units, the Chroma 61830HF/61845HF/61860HF range supports parallel operation of up to four units for a maximum output of 240kVA. Even in parallel operation, users can switch automatically between single-phase and three-phase output modes with one touch from the master-unit GUI, providing broader and more flexible power configuration options.

This scalable power architecture, together with high-efficiency energy recovery, high-bandwidth design, excellent output stability, and transient performance, makes the benchtop models well suited to automotive applications such as EVs and charging stations, clean-energy systems such as PV inverters, microgrids, and energy storage, and AI data center power applications such as server power modules and server power racks or cabinets.

Chroma 61830HF / 61845HF / 61860HF

Chroma 61800-90HF / 61800-120HF / 61800-240HF / 61800-360HF

For higher power test requirements, the 61800-90HF, 61800-120HF, 61800-240HF, and 61800-360HF rack models use high-precision three-phase synchronization to support up to four racks in parallel, with total output capacity reaching 1.44MVA. The high-power parallel architecture targets AI data center power infrastructure, including Power Rack systems, SSTs, and HVDC distribution equipment. It also supports testing of Megawatt Charging Systems (MCS), large-scale energy storage systems (ESS), grid-connected power conversion systems (PCS), and string PV inverters.

The modular power-stage design also simplifies service and troubleshooting. Only the affected power module needs to be replaced to restore the system to operation, enabling fast fault resolution in high-power parallel test configurations and significantly reducing maintenance downtime.

*For applications requiring more than four 61800HF Series units in parallel, please call for availability.

Chroma 61800-90HF / 61800-120HF / 61800-240HF / 61800-360HF

Intuitive Touch Interface

The Chroma 61800HF Series combines a modern industrial design with practical operating logic, providing a dual-interface platform built around a full touchscreen and tactile physical keys. Users can choose between virtual and physical numeric keypads, while carefully designed icons and shortcut keys improve operating efficiency. For protection settings, communication settings, advanced programming, and voltage ramp-up/ramp-down testing, the dual-interface design allows users to switch freely between smart touch control and precise physical feedback, enabling a complete and seamless operating experience.

Chroma 61860HF Regenerative Grid Simulator

  1. Main Page
  2. Lock Screen
  3. Full-Screen Mode (measurement values)
  4. Unified Three-Phase Settings
  5. Total Power Display
  1. Three-Phase / Single-Phase / Split-Phase Mode
  2. Output ON
  3. Advanced Settings
  4. Output Mode Selection
  5. Numeric Keypad
  1. Built-in Shortcuts
  2. Custom Shortcuts (A to F)
  3. Cursor Mode
  4. Keypad Mode
  5. Voltage / Frequency Settings
  1. Measurement Display
  2. More Measurements (swipe left / right)
  3. Advanced Function Shortcut
  4. Esc Key
  5. Shift Shortcut Toggle

 

The touchscreen interface uses a clear and intuitive GUI to simplify the complex settings and measurement screens typically associated with AC power products. With easily recognizable icons and visual guidance, users can quickly understand each function without navigating deep menu structures, streamlining professional test workflows more intuitive and efficient.

The physical keys support not only a standard numeric keypad, Cursor mode, and Keypad mode, but also Shift combination shortcuts that provide one-touch access to core function screens, greatly reducing time spent navigating layered menus. Custom shortcut keys also allow users to assign frequently used functions or setting pages to dedicated keys A through F, enabling a personalized workflow and greater operating efficiency.

Softpanel Interface

The Chroma 61800HF Series can be used with SoftPanel, the graphical control software designed for the 61800 series. Its multifunction graphical interface and easy operation provide users with a more flexible way to run tests. The software also includes preset IEC immunity test functions for related power-standard evaluations, including IEC 61000-4-11, -4-13, -4-14, -4-27, and -4-28.

Software Main Page
Chroma 61860HF Regenerative Grid Simulator
Transient Voltage Programming
Chroma 61860HF Regenerative Grid Simulator
Inter-Harmonic Testing
Chroma 61860HF Regenerative Grid Simulator

 

Voltage Dips, Short Interruptions, Voltage Variations
Chroma 61860HF Regenerative Grid Simulator
Distorted Waveform Editing
Chroma 61860HF Regenerative Grid Simulator
Measurement Data Report
Chroma 61860HF Regenerative Grid Simulator

Domande su Prodotti

Select the models you wish to get a quote and click the button "Add to Inquiry Cart" below the table.
You may select multiple items at once. Click the inquiry cart icon on the right hand side of webpage to complete your inquiry.

Tutte le specifiche sono passibili di modifiche senza preavviso.
Selezione
Numero del modello
Descrizione

Simulatore rigenerativo di rete elettrica

Simulatore rigenerativo di rete elettrica 30kVA*

Simulatore rigenerativo di rete elettrica 45kVA*

Simulatore rigenerativo di rete elettrica 60kVA

Simulatore rigenerativo di rete elettrica 90kVA*

Simulatore rigenerativo di rete elettrica 120kVA*

Simulatore rigenerativo di rete elettrica 240kVA*

Simulatore rigenerativo di rete elettrica 360kVA

SoftPanel for 61800 Series

*Call for availability