Quick Menu

Power Electronic Component Automatic Test System

PowerConversionSystem(PCS)ATS Model8000
Power Conversion System (PCS) ATS
Model 8000
The power conversion system (PCS) is a device connected between the battery system and the grid to achieve bidirectional conversion of energy. The versatile Chroma 8000 ATS serves as the base and can be customized for automated testing and verification of energy storage inverters. Combined with bidirectional test and measurement devices, the equipment performs PCS grid, performance, input and output characteristics, and protection characteristics testing, as well as photovoltaic (PV) characteristics testing.

Battery Simulator

BidirectionalDCPowerSupply Model62000DSeries
  • CE Mark
  • Rohs 2 Compliant
  • Taiwan Excellence 2023
Bidirectional DC Power Supply
Model 62000D Series
  • 2 in 1 Bidirectional DC Power Supply + Regenerative Load
  • Rating: Voltage 0-1800V, Current up to 540A, Power up to 540kW
  • PV, Battery, Fuel Cell simulation
16CHBatteryCellSimulator Model87001
  • CE Mark
  • Rohs 2 Compliant
16CH Battery Cell Simulator
Model 87001
  • Operating mode: CC/CP
  • Channel power: 25W, Channel voltage: 5V, Channel current: 5A (parallelable)
  • Bidirectional power supply design
  • 480-cell battery pack voltage simulation ability (240 cells in series and 2 cells in parallel)

Battery Pack/ Module Test System

BatteryPackATS Model8720
  • CE Mark
Battery Pack ATS
Model 8720
  • Specifically designed for battery production line, or battery development testing.
  • Increases QA efficiency by up to 80% 
  • Inspection of BMS functions, connector withstand voltage, consistency, and performance of battery module
  • Charge/discharge power range: 5kW ~ 350kW
  • Charge/discharge voltage/current range: 0V~900V/0A~1000A
RegenerativeBatteryPackTestSystem Model17020
  • CE Mark
Regenerative Battery Pack Test System
Model 17020
  • Voltage 20V/60V/100V/200V/500V for EV, storage battery pack/module test
  • Max 60 independant channels, parallel for high current
RegenerativeBatteryPackTestSystem Model17040
  • CE Mark
  • Taiwan Excellence 2019
Regenerative Battery Pack Test System
Model 17040
  • Voltage range: 60~1000V, Current range : 0~750A, Power range : 0~300kW
  • Accuracy current / voltage measurement (±0.05%FS / ±0.02%FS)
  • Multiple voltage / current ranges for auto ranging function
  • Conforms to international standards for battery testing: IEC, ISO, UL, and GB/T, etc
     
RegenerativeBatteryPackTestSystem Model17040E
  • CE Mark
  • Rohs 2 Compliant
Regenerative Battery Pack Test System
Model 17040E
  • High-power testing equipment up to 1,700V/ 4800A/ 1.2MW
  • Multiple safety protections for personnel safety risk management and control of battery testing
  • Flexible Integration for automated battery verification solutions

Power Electronics Test Instruments

ACandDCElectronicLoad Model63800Series
  • CE Mark
AC and DC Electronic Load
Model 63800 Series
  • Power rating: 1800W, 3600W, 4500W
  • Parallel/3-Phase function (AC mode only)
  • Constant & Rectified load modes for AC loading
  • CC, CR, CV, CP for DC loading
BidirectionalDCPowerSupply Model62000DSeries
  • CE Mark
  • Rohs 2 Compliant
  • Taiwan Excellence 2023
Bidirectional DC Power Supply
Model 62000D Series
  • 2 in 1 Bidirectional DC Power Supply + Regenerative Load
  • Rating: Voltage 0-1800V, Current up to 540A, Power up to 540kW
  • PV, Battery, Fuel Cell simulation
RegenerativeGridSimulator Model61809/61812/61815
  • CE Mark
  • Rohs 2 Compliant
  • Taiwan Excellence 2022
Regenerative Grid Simulator
Model 61809/61812/61815
  • Output power rating: 9kVA~15kVA
  • Output voltage: 0~350V
  • High Power Density 15kVA in 3UH
  • Intuitive Touch Panel Interface
SolarArraySimulator Model62000H-SSeries
  • CE Mark
  • Rohs 2 Compliant
Solar Array Simulator
Model 62000H-S Series
  • High-voltage 1800V for string PV inverter test solution
  • 5kW/10kW/15kW/18kW up to 1MW
  • Fast Transient Response Solar Array Simulation
  • Build-in dynamic MPPT test profile of EN50530/Sandia/CGC-GF004/CGC/GF035/NB-T32004
RegenerativeGridSimulator Model61830/61845/61860/61800-100/61800-100(800VLN)
  • CE Mark
  • Taiwan Excellence 2018
Regenerative Grid Simulator
Model 61830/61845/61860/61800-100/61800-100(800VLN)
  • Output power rating: 30kVA~60kVA max. 300kVA (Parallel connect up to 5 units)
  • Three phase output voltage 0~300V/30Hz~100Hz
  • Full 4-quadrant with regenerative capability
  • Capable of Power Line Distortion simulation

Electrical Safety Testing

PartialDischargeTester Model19501-K/19500Series
  • CE Mark
  • Rohs 2 Compliant
Partial Discharge Tester
Model 19501-K/19500 Series
  • Built-in Hipot test and PD detector function in one instrument
  • Programmable voltage output: 0.1KVac~10KVac
  • PD (Partial Discharge) detection range: 1 pC~2000 pC
  • High accuracy and resolution current meter: 0.01uA~300uA
ElectricalSafetyAnalyzer Model19032/19032-P
  • CE Mark
  • Rohs 2 Compliant
  • TUV
Electrical Safety Analyzer
Model 19032/19032-P
  • 5 In 1 (ACV/DCV/ IR/GB/LC Test)
  • 500VA Power Rating
  • Twin-Port function
  • Open / Short Check(OSC)
HipotAnalyzer Model19055/19055-C
  • CE Mark
  • Rohs 2 Compliant
Hipot Analyzer
Model 19055/19055-C
  • Hipot test
    ACW 5kV/100mA
    DCW 6kV/25mA 
  • Insulation Resistance test
    5kVmax
    1MΩ~50GΩ 
  • 500VA output
ElectricalEquipmentATS Model8900
  • CE Mark
Electrical Equipment ATS
Model 8900
  • Open architecture software
  • Expandable hardware