Quick Menu

Hybrid PV Inverter Test Solution

ACandDCElectronicLoad Model63800Series
  • CE Mark
AC and DC Electronic Load
Model 63800 Series
  • Power rating: 1800W, 3600W, 4500W
  • Parallel/3-Phase function (AC mode only)
  • Constant & Rectified load modes for AC loading
  • CC, CR, CV, CP for DC loading
ElectricalSafetyAnalyzer Model19032/19032-P
  • CE Mark
  • Rohs 2 Compliant
  • TUV
Electrical Safety Analyzer
Model 19032/19032-P
  • 5 In 1 (ACV/DCV/ IR/GB/LC Test)
  • 500VA Power Rating
  • Twin-Port function
  • Open / Short Check(OSC)
DigitalPowerMeter Model66203/66204
  • CE Mark
  • Rohs 2 Compliant
Digital Power Meter
Model 66203/66204
  • Provides 0.1% FS measurement accuracy
  • Three phase measurement application
  • Voltage range: 15Vrms~600Vrms (6 Range)
  • Current range: 5mArms~20Arms (8 Range)
  • Wiring mode: 1P2W, 1P3W, 3P3W, 3V3A, 3P4W
SolarArraySimulator Model62000H-SSeries
  • CE Mark
  • Rohs 2 Compliant
Solar Array Simulator
Model 62000H-S Series
  • High-voltage 1800V for string PV inverter test solution
  • 5kW/10kW/15kW/18kW up to 1MW
  • Fast Transient Response Solar Array Simulation
  • Build-in dynamic MPPT test profile of EN50530/Sandia/CGC-GF004/CGC/GF035/NB-T32004
RegenerativeGridSimulator Model61830/61845/61860/61800-100/61800-100(800VLN)
  • CE Mark
  • Taiwan Excellence 2018
Regenerative Grid Simulator
Model 61830/61845/61860/61800-100/61800-100(800VLN)
  • Output power rating: 30kVA~60kVA max. 300kVA (Parallel connect up to 5 units)
  • Three phase output voltage 0~300V/30Hz~100Hz
  • Full 4-quadrant with regenerative capability
  • Capable of Power Line Distortion simulation
PVInverterATS Model8000
  • CE Mark
PV Inverter ATS
Model 8000
  • High performance hardware device and software architecture
  • Meets IEEE1547, 1547.1, UL1741, GB/T 19939, NB/T 32004, CGC/GF004/GF035 preliminary test requirements.
  • Compliance with Sandia and EN50530 regulations and built-relevant test items
  • Solar Array Simulation

PCS Test Solution

PowerConversionSystem(PCS)ATS Model8000
Power Conversion System (PCS) ATS
Model 8000
Power Conversion Systems (PCS) are devices connected between the battery system and the grid to achieve bidirectional energy conversion. The Chroma 8000 ATS is a customizable system designed specifically for automated testing and verification of PCS. With the 8000 ATS as a base and equipped with the Chroma 61800, 62000D, and 17040 grid/battery simulators and measurement instruments, this versatile platform can perform PCS grid-connected testing, PCS performance testing, PCS output/input characteristic testing, PCS protection characteristic testing, and photovoltaic characteristic testing. These tests meet the preliminary testing requirements of IEC62933, Chinese national standards GB/T34120 and GB/T34133, Korean standard SGSF-04-2012-07, and the German low-voltage grid connection standard VDE-AR-N 4105. Users only need to confirm the required test conditions and specifications, and the optimized PCS ATS is ready to perform automated PCS testing.