Quick Menu

Power Electronic Component Automatic Test System

PowerConversionSystem(PCS)ATS Model8000
Power Conversion System (PCS) ATS
Model 8000
Power Conversion Systems (PCS) are devices connected between the battery system and the grid to achieve bidirectional energy conversion. The Chroma 8000 ATS is a customizable system designed specifically for automated testing and verification of PCS. With the 8000 ATS as a base and equipped with the Chroma 61800, 62000D, and 17040 grid/battery simulators and measurement instruments, this versatile platform can perform PCS grid-connected testing, PCS performance testing, PCS output/input characteristic testing, PCS protection characteristic testing, and photovoltaic characteristic testing. These tests meet the preliminary testing requirements of IEC62933, Chinese national standards GB/T34120 and GB/T34133, Korean standard SGSF-04-2012-07, and the German low-voltage grid connection standard VDE-AR-N 4105. Users only need to confirm the required test conditions and specifications, and the optimized PCS ATS is ready to perform automated PCS testing.

Battery Simulator

BidirectionalDCPowerSupply Model62000DSeries
  • CE Mark
  • Rohs 2 Compliant
  • Taiwan Excellence 2023
Bidirectional DC Power Supply
Model 62000D Series
  • 2 in 1 Bidirectional DC Power Supply + Regenerative Load
  • Rating: Voltage 0-1800V, Current up to 540A, Power up to 540kW
  • PV, Battery, Fuel Cell simulation
16CHBatteryCellSimulator Model87001
  • CE Mark
  • Rohs 2 Compliant
16CH Battery Cell Simulator
Model 87001
  • Operating mode: CC/CP
  • Channel power: 25W, Channel voltage: 5V, Channel current: 5A (parallelable)
  • Bidirectional power supply design
  • 480-cell battery pack voltage simulation ability (240 cells in series and 2 cells in parallel)
BatterySimulator Model17020/17040
  • CE Mark
Battery Simulator
Model 17020/17040
  • Multichannel battery packs state simulation 
  • Ability to follow the battery cell curve behavior to simulate battery state
  • Ability to set frequently used parameters for battery pack and rapidly customize initial output state
  • Allows for smooth and rapid current charge and discharge switching without interruption for bidirectional components

Battery Pack/ Module Test System

RegenerativeBatteryPackTestSystem Model17040E
  • CE Mark
  • Rohs 2 Compliant
Regenerative Battery Pack Test System
Model 17040E
  • High-power testing equipment up to 1,700V/ 4800A/ 1.2MW
  • Multiple safety protections for personnel safety risk management and control of battery testing
  • Flexible Integration for automated battery verification solutions
RegenerativeBatteryPackTestSystem Model17040
  • CE Mark
  • Taiwan Excellence 2019
Regenerative Battery Pack Test System
Model 17040
  • Voltage range: 60~1000V, Current range : 0~1500A, Power range : 0~600kW
  • High accuracy current/voltage measurement (±0.05%FS / ±0.02%FS)
  • Multiple voltage / current ranges for auto ranging function
  • Meets international standards for battery testing: IEC, ISO, UL, and GB/T, etc.
     
RegenerativeBatteryPackTestSystem Model17020
  • CE Mark
Regenerative Battery Pack Test System
Model 17020
  • Voltage 20V/60V/100V/200V/500V for EV, storage battery pack/module test
  • Max 60 independant channels, parallel for high current
RegenerativeBatteryPackTestSystem Model17020E
Regenerative Battery Pack Test System
Model 17020E
  • Charge/discharge modes (CC, CV, CP)
  • Power: 10kW, 20kW per channel (Up to 80kW by parallel)
  • Voltage: 60V,100V, 200V
  • Current: 180A, 100A per channel (Up to 800A by parallel)
BatteryPackEOLATS Model8720
  • CE Mark
Battery Pack EOL ATS
Model 8720
  • Specifically designed for battery production line, or battery development testing
  • Increases QA efficiency by up to 80% 
  • Inspection of BMS functions, connector withstand voltage, consistency, and performance of battery module
  • Charge/discharge power range: 5kW ~ 350kW
  • Charge/discharge voltage/current range: 0V~900V/0A~1000A
BMSPowerHILTestbed Model8630
BMS Power HIL Testbed
Model 8630
  • Integrated Fault Injection Unit for comprehensive ISO26262
  • Up to 1200V/600A battery module simulation voltage and current, actual verification and calibration of SOC, SOH and other BMS parameters
  • Test BMS protection mechanisms for OVP, UVP, OCP, OTP or UTP under static or dynamic conditions
  • Supports CAN, CAN FD, LIN interfaces

Power Electronics Test Instruments

BidirectionalDCPowerSupply Model62000DSeries
  • CE Mark
  • Rohs 2 Compliant
  • Taiwan Excellence 2023
Bidirectional DC Power Supply
Model 62000D Series
  • 2 in 1 Bidirectional DC Power Supply + Regenerative Load
  • Rating: Voltage 0-1800V, Current up to 540A, Power up to 540kW
  • PV, Battery, Fuel Cell simulation
ACandDCElectronicLoad Model63800Series
  • CE Mark
AC and DC Electronic Load
Model 63800 Series
  • Power rating: 1800W, 3600W, 4500W
  • Parallel/3-Phase function (AC mode only)
  • Constant & Rectified load modes for AC loading
  • CC, CR, CV, CP for DC loading
RegenerativeGridSimulator Model61809/61812/61815
  • CE Mark
  • Rohs 2 Compliant
  • Taiwan Excellence 2022
Regenerative Grid Simulator
Model 61809/61812/61815
  • Output power rating: 9kVA~15kVA
  • Output voltage: 0~350V
  • High Power Density 15kVA in 3UH
  • Intuitive Touch Panel Interface
SolarArraySimulator Model62000H-SSeries
  • CE Mark
  • Rohs 2 Compliant
Solar Array Simulator
Model 62000H-S Series
  • High-voltage 1800V for string PV inverter test solution
  • 5kW/10kW/15kW/18kW up to 1MW
  • Fast Transient Response Solar Array Simulation
  • Build-in dynamic MPPT test profile of EN50530/Sandia/CGC-GF004/CGC/GF035/NB-T32004
RegenerativeGridSimulator Model61830/61845/61860/61800-100/61800-100(800VLN)
  • CE Mark
  • Taiwan Excellence 2018
Regenerative Grid Simulator
Model 61830/61845/61860/61800-100/61800-100(800VLN)
  • Output power rating: 30kVA~60kVA max. 300kVA (Parallel connect up to 5 units)
  • Three phase output voltage 0~300V/30Hz~100Hz
  • Full 4-quadrant with regenerative capability
  • Capable of Power Line Distortion simulation

Electrical Safety Testing

PartialDischargeTester Model19501-K
  • CE Mark
  • Rohs 2 Compliant
Partial Discharge Tester
Model 19501-K
  • Built-in Hipot test and PD detector function in one instrument
  • Programmable voltage output: 0.1KVac~10KVac
  • PD (Partial Discharge) detection range: 1 pC~2000 pC
  • High accuracy and resolution current meter: 0.01uA~300uA
ElectricalSafetyAnalyzer Model19032/19032-P
  • CE Mark
  • Rohs 2 Compliant
  • TUV
Electrical Safety Analyzer
Model 19032/19032-P
  • 5 In 1 (ACV/DCV/ IR/GB/LC Test)
  • 500VA Power Rating
  • Twin-Port function
  • Open / Short Check(OSC)
HipotAnalyzer Model19055/19055-C
  • CE Mark
  • Rohs 2 Compliant
Hipot Analyzer
Model 19055/19055-C
  • Hipot test
    ACW 5kV/100mA
    DCW 6kV/25mA 
  • Insulation Resistance test
    5kVmax
    1MΩ~50GΩ 
  • 500VA output
ElectricalEquipmentATS Model8900
  • CE Mark
Electrical Equipment ATS
Model 8900
  • Open architecture software
  • Expandable hardware